国王vs开拓者enjpkr

客戶中心

客戶評價

国王vs开拓者 www.mtkrz.club 您當前的位置:国王vs开拓者 > 客戶評價

From Ardea Bio Science

The quality assurance (QA) unit consists of four full time GLP members, and members of the QAU attend SQA meetings every year. The QA manager has been RQAP-GLP certified since 2009. A sign at the entrance to the preclinical building identifies it as a GLP area and instructs to comply with all SOPs. Personal protective equipment standards are taken very seriously. All equipment for GLP use is clearly labeled as GLP. Equipment logbooks are maintained near each piece of equipment and all equipment records from previous years had been archived at the time of inspection. Pipettes are calibrated quarterly. Instruments in use for GLP formulation analysis all indicate the last date of maintenance and calibration and show the next dates due - labels are firmly secured to the equipment and instruments. In the event of power failure, power is switch- ed to generators within 10 minutes. Temperature and humidity in the test article storage room are monitored by a biannually calibrated thermo hygrometer. Sample storage environmental monitoring performed using SENSATRONICS.

The Medicilon archive meets regulatory expectatio- ns for security. The room is locked, it is accessible only by the archivist and entry to the room is tracked with a sign-in sheet. The Archive is protected by a water sprinkler system and archived materials are protected from water damage in plastic bags. Electronic archived materials are stored on CD/DVD in metal boxes locked in a separate cabinet, but within the same room. Pest control material is dispersed among the cabinets. Annual GLP refresher training is performed; training records are maintained in the group leader’s cabinets. Deviations from the SOPs and protocol in the reviewed method validation were properly documented and the impact appropriately addressed by the study director. QC review was clearly documented throughout the raw data. The QA statement indicated several inspections were performed and all equipment use was tracked appropriately...

Quality Control & Assurance

QC review was clearly documented throughout the raw data. The QA statement indicated several inspections were performed and all equipment use was tracked appropriately.


From SK Life Science R&D Park

The results of an intensive three days audit onsite of GLP systems and procedures, as well as site and personnel, operating systems and procedures, and raw data and final report from one non-GLP study lead to the conclusion that Medicilon is qualified and capa- ble of conducting non-clinical GLP studies in compliance with the US FDA GLP’s. The personnel who participated the audit were knowledgeable and professional. The results of an intensive thr- ee day audit as well as facilities and training records and proce- dures lead to the conclusion that the facility is qualified and capable of conducting in compliance with accepted standards of practice and the GLP’s.

High Caliber Scientific Staff

The personnel who participated the audit were knowledgeable and professional.


    Sepracor, (now Sunovion) a biotech company of Boston presented Excellent Perforamance Award to Medicilon in recognition of excellent services and contributions to its discovery research

    Roche R&D China presents a medal of Most Valuable Partner Award to Medicilon in recognition of excellent partnership

天天乐游戏下载 怎样网上买彩票 河南十一选五遗漏 路边卖刮刮乐赚钱吗 重庆时时彩开奖记录下载 吉林十一选五走势图真牛 危化品运输公司赚钱吗 陕西十一选五预测号码 股票行情今天涨停股票 双色球蓝球复式兑奖 腾讯棋牌游戏中心官网 北京快乐8死人 甘肃11选5预测 澳洲幸运10二十四小时开奖 安徽十一选五走势图百度彩票 大乐透300坐标走势